Stimpod NMS450X

Objective TOF neuromuscular monitoring of muscle relaxants during general anaesthesia.

The Stimpod NMS450X features OneTouch NMT™ technology which enables the user to monitor an entire case from electrode placement to extubation at the press of a single button.

Once initiated, the Stimpod will automatically confirm and optimise the electrode placement by assigning the appropriate supramaximal current, begin Train of Four Monitoring (TOF Monitoring) and move to Post Tetanic Count (PTC) when a deep/profound block is achieved.

When the patient begins the reversal process, the Stimpod neuromuscular monitor will automatically reinitiate TOF monitoring until the patient is 90%+ recovered. No manual intervention is required to manage the process. Along the way, the Stimpod will detect and notify the user of the depth of the neuromuscular blockade.

Categories: ,

Description

The Stimpod NMS 450X : Quantitative NMT Monitoring
Train of Four | Post Tetanic Count | Double Burst | Tetanus | Twitch

Nerve Mapping & Locating

    • OneTouch NMT Monitoring
    • Electrode Placement Verification
    • Quick Setup & No Calibration
    • Handheld
    • Data Connectivity
    • Reusable Sensor
    • Standard ECG Electrode Compatible
    • Quantitative NMT Monitoring reduces incidence of residual paralysis, increases operating room throughput and lowers cost
    • 23 years of AMG research proves it identifies residual paralysis in 97% of patients

 

Key Features
Accurate and real-time NMT monitoring
Supports Train-of-Four (TOF), Post-Tetanic-Count (PTC), Double Burst (DB), Tetanus and Twitch stimulation modes for accurate Neuromuscular Monitoring.

Electrode placement verification
Verify effective electrode placement and optimal stimulation current.

Data connectivity
Transfer case data to electronic medical records with ease.

Quick setup and no calibration
Patient can be monitored instantly and at any time during the procedure.

Workflow guidance
Step-by-step prompts for proper setup and use.

Reusable 3D AMG Sensor
Reusable sensor design saves running costs compared to devices with disposable sensors.

Versatile Sensor Placement
The 3D AMG sensor can be placed on the thumb, toe or face.

Standard ECG Electrode Compatible
Compatible with off-the-shelf ECG electrodes, allowing hospitals the freedom to purchase or use any existing electrode.

Nerve mapping and locating
Includes combined mapping and location functionality for peripheral nerve blocks.

Handheld or IV pole mount
Handheld portability with a rapid quick-snap IV pole mountable design makes it easy to move between the OR, PACU and ICU.